Assessing Data Center Infrastructure for Reduced Energy Consumption

Assessing Data Center Infrastructure for Reduced Energy Consumption

The increasing demand for data storage and processing has led to a significant rise in energy consumption by data centers worldwide. According to the US Environmental Protection Agency (EPA), data centers account for approximately 1 of global electricity consumption, which translates to around 13 billion annually in the United States alone. This staggering figure highlights the need for data center operators to reassess their infrastructure and implement measures to reduce energy consumption.

A comprehensive assessment of a data centers infrastructure is essential to identify areas where energy savings can be achieved. This involves analyzing various aspects, including cooling systems, power distribution, server utilization, and overall facility design. By pinpointing inefficiencies and adopting sustainable practices, data centers can significantly reduce their carbon footprint while minimizing operational costs.

To begin the assessment process, data center operators should consider the following steps:

1. Conduct a thorough energy audit: Hire a third-party auditor to evaluate the data centers energy usage patterns, identify areas of inefficiency, and provide recommendations for improvement.
2. Gather baseline data: Collect historical energy consumption data, server utilization statistics, and cooling system performance metrics to establish a baseline for future comparisons.
3. Analyze facility design and layout: Review the physical layout of the data center, including the location of servers, storage systems, and power distribution units (PDUs).

Cooling Systems:

  • Cooling systems are one of the primary energy consumers in data centers, accounting for approximately 30-40 of total energy expenditure.

  • Air-side economization: Implement air-side economization by using outdoor air for cooling during mild weather conditions. This can be achieved through the use of economizers, which draw in outside air to cool servers and reduce the need for mechanical cooling systems.

  • Water-side economization: Utilize water-side economization by using cooled water from a chilled water system to cool data center equipment. This approach reduces the energy required for mechanical cooling while maintaining optimal server temperatures.

  • Free cooling: Leverage free cooling techniques, such as evaporative cooling or adiabatic cooling, which can significantly reduce the energy consumption of cooling systems.


  • Power Distribution and Utilization:

  • Power distribution is another critical aspect of data center infrastructure, with PDUs and switchgear often accounting for a substantial portion of total energy expenditure.

  • Server utilization: Analyze server utilization patterns to identify underutilized or idle servers. Consolidating workloads onto fewer, more efficient servers can lead to significant energy savings.

  • Power density: Optimize power distribution by designing facilities with high power densities, reducing the number of PDUs and switchgear required while minimizing cable lengths and associated losses.

  • Power quality monitoring: Implement real-time power quality monitoring systems to detect anomalies in voltage, current, or frequency fluctuations that can impact equipment performance and energy efficiency.


  • Energy Efficiency Strategies:

  • Implementing virtualization: Virtualize server infrastructure to optimize resource allocation, reduce the number of physical servers required, and decrease overall energy consumption.

  • Using high-efficiency equipment: Upgrade to high-efficiency cooling systems, PDUs, and switchgear that minimize energy losses while providing reliable power distribution.

  • Design for scalability: Design data center facilities with modular, scalable architectures to accommodate future growth while minimizing the need for new infrastructure investments.


  • Challenges and Considerations:

  • Data centers often struggle to balance energy efficiency with uptime and availability requirements. Operators must carefully weigh the trade-offs between efficiency gains and potential risks to system reliability.

  • IT staff may resist changes to data center infrastructure, citing concerns about equipment compatibility or the impact on existing applications.

  • Implementing new energy-efficient technologies can be costly, especially for larger facilities. Data center operators must carefully evaluate the return on investment (ROI) for proposed initiatives.


  • QA Section:

    Q: What are some common energy consumption patterns in data centers?

    A: Common energy consumption patterns include:
    Cooling systems accounting for 30-40 of total energy expenditure
    Power distribution and utilization consuming approximately 20-25
    Server utilization and infrastructure optimization influencing around 15-20

    Q: How can I determine the ideal power density for my data center facility?

    A: Consider factors such as climate, equipment type, and operational requirements when determining optimal power densities. For example:
  • Data centers in hot climates may require higher power densities to account for increased cooling loads.

  • High-density servers or compute-intensive applications may necessitate lower power densities to prevent overheating.


  • Q: What are the benefits of implementing virtualization in my data center?

    A: Virtualization offers several advantages, including:
    Improved server utilization through workload consolidation
    Reduced energy consumption due to decreased physical server count
    Simplified resource allocation and management

    Q: How can I measure the effectiveness of an energy efficiency project?

    A: Establish baseline metrics before implementing energy-saving initiatives, and track subsequent improvements in areas such as:
    Energy consumption per square foot or watt
    Cooling system performance (e.g., PUE, CRAC)
    Server utilization rates

    Q: What are some common misconceptions about data center infrastructure and energy efficiency?

    A: Common myths include:
    Data centers must always prioritize uptime over energy efficiency.
  • Energy-efficient technologies are too expensive to justify investment.

  • Higher cooling loads necessitate more powerful cooling systems.


  • By addressing the intricacies of data center infrastructure and implementing targeted strategies for reduced energy consumption, operators can create a more sustainable, efficient, and cost-effective environment for their IT assets.